EYS Series Ex Explosion Protected Conduit Sealing Fittings to be used in hazardous area with the
following specifications:
For IEC electrical systems
Ex II 2 G EEx d IIC
EYS for vertical only installations, or for both vertical or horizontal positions
EZS for installation at any angle 1/2″ to 2″
Bag Series Explosion-Proof Seal Bushings
Catalogue Number Logic
Cable Glands And Bushings
Technical Data
Explosion Protection To
-Cenelec
-Iec
Can Be Used In
Zone 1 And Zone 2
Zone 21 And Zone 22
Ex D Enclosure, Copper-Free Aluminium, Powder Coated
External Surface.
Widely Used For Isolating Seal Between Pipes Or Pipes And
Explosion-Proof Enclosures.
Jual Sealing Fitting Explosion Proof Jakarta Exproof Indonesia
This seal fitting is an accessories for Installation BAG Series Explosion-proof Seal Bushings Catalogue number logic Cable Glands and Bushings Technical data Explosion protection to -CENELEC -IEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Ex d enclosure, copper-free aluminium, powder coated external surface. Widely used for isolating seal between pipes or pipes and explosion-proof enclosures.Certifitace Atex Internasional / European ATEX Standart / American FM Standart II 2 G Ex d IIC Gb
II 2 D Ex t IIIC Db IP66
DNV 12 ATEX_____; PCEC (China)
EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009
IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008
Copper-free aluminium; powder coated external surface.
Window grey (RAL 7040)
IP66
EYSX Explosionproof Sealing Fittings to be used in hazardous area with the following specifications:
Class I, Div. 1 & 2, Groups B, C, D
Class II, Div. 1, Groups E, F, G
40% wire fill capacity to allow uninterrupted runs in conduit system
For both vertical or horizontal installations 1/2″ to 4″
Sealing Fitting Explosionproof & Epoxy Sealing Compound Fllings to be used in hazardous area with the
following specifications:
Class I, Div. 1 & 2, Groups C, D
Seals vertical conduit risers into switchgear and motor control equipment and enclosures
Seals horizontal conduit runs at enclosures when used with TSC sealing compound
1/2″ to 5″
EYS and EZS Series Explosionproof Conduit Sealing Fittings to be used in hazardous area with the
following specifications:
Class I, Div. 1 & 2, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
EYS for vertical only installations, or for both vertical or horizontal positions
EZS for installation at any angle
1/2″ to 6″
EYDX Explosionproof Conduit Sealing Fittings with Drain breather to be used in hazardous area with the
following specifications:
Class I, Div. 1 & 2, Groups B, C, D
Class II, Div. 1, Groups E, F, G
40% wire fill capacity to allow uninterrupted runs in conduit system
Prevents accumulation of condensate above seal through continuous drainage
1/2″ to 3″
EYD Explosionproof Sealing Fittings to be used in hazardous area with the following specifications:
Class I, Div. 1 & 2, Groups B, C, D
Class II, Div. 1, Groups E, F, G
Prevents accumulation of condensate above seal through continuous drainage
1/2″ to 4″
EYSA Flameproof Conduit Sealing Fittings to be used in hazardous area with the following specifications:
For IEC electrical systems
Zone 1, 2, 21, 22
For vertical only installations, or for both vertical or horizontal positions
20mm to 50mm
EYSR Series Retrofit Sealing Fittings to be used in hazardous area with the
following specifications:
Class I, Div. 2 only, Groups C, D
Class II, Div. 2, Groups E, F, G
Replaces installed EYS or EYD sealing fitting without disassembly of conduit system
3/4″ to 4″
Jual Sealing Fitting Explosion Proof Jakarta Exproof Indonesia
This seal fitting is an accessories for Installation BAG Series Explosion-proof Seal Bushings Catalogue number logic Cable Glands and Bushings Technical data Explosion protection to -CENELEC -IEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Ex d enclosure, copper-free aluminium, powder coated external surface. Widely used for isolating seal between pipes or pipes and explosion-proof enclosures.Certifitace Atex Internasional / European ATEX Standart / American FM Standart II 2 G Ex d IIC Gb
II 2 D Ex t IIIC Db IP66
DNV 12 ATEX_____; PCEC (China)
EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009
IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008
Copper-free aluminium; powder coated external surface.
Window grey (RAL 7040)
IP66
Explosion Proof Sealing Fitting Jakarta, Sealing Fitting Explosion Proof Jakarta, Sealing Fitting Explosion Proof G Type
Bag Series Explosion-Proof Seal Bushings
Catalogue Number Logic
Cable Glands And Bushings
Technical Data
Explosion Protection To
-Cenelec
-Iec
Can Be Used In
Zone 1 And Zone 2
Zone 21 And Zone 22
Ex D Enclosure, Copper-Free Aluminium, Powder Coated
External Surface.
Widely Used For Isolating Seal Between Pipes Or Pipes And
Explosion-Proof Enclosures.