SEALING FITTINGS

jual sealing fitting

Explosion Proof Sealing Fitting Jakarta, Sealing Fitting Explosion Proof Jakarta, Sealing Fitting Explosion Proof G Type

EYS Series Ex Explosion Protected Conduit Sealing Fittings to be used in hazardous area with the
following specifications:

  • For IEC electrical systems
    Ex II 2 G EEx d IIC
    EYS for vertical only installations, or for both vertical or horizontal positions
    EZS for installation at any angle 1/2″ to 2″

Bag Series Explosion-Proof Seal Bushings
Catalogue Number Logic
Cable Glands And Bushings
Technical Data
Explosion Protection To
-Cenelec
-Iec
Can Be Used In
Zone 1 And Zone 2
Zone 21 And Zone 22
Ex D Enclosure, Copper-Free Aluminium, Powder Coated
External Surface.
Widely Used For Isolating Seal Between Pipes Or Pipes And
Explosion-Proof Enclosures.

jual sealing fitting jakarta

Jual Sealing Fitting Explosion Proof Jakarta Exproof Indonesia

This seal fitting is an accessories for Installation
BAG Series Explosion-proof Seal Bushings
Catalogue number logic
Cable Glands and Bushings
Technical data
Explosion protection to
-CENELEC
-IEC
Can be used in
Zone 1 and Zone 2
Zone 21 and Zone 22
Ex d enclosure, copper-free aluminium, powder coated
external surface.
Widely used for isolating seal between pipes or pipes and
explosion-proof enclosures.Certifitace Atex Internasional / European ATEX Standart / American FM Standart
II 2 G Ex d IIC Gb
II 2 D Ex t IIIC Db IP66
DNV 12 ATEX_____; PCEC (China)
EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009
IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008
Copper-free aluminium; powder coated external surface.
Window grey (RAL 7040)
IP66

EYSX Explosionproof Sealing Fittings to be used in hazardous area with the following specifications:

Class I, Div. 1 & 2, Groups B, C, D
Class II, Div. 1, Groups E, F, G
40% wire fill capacity to allow uninterrupted runs in conduit system
For both vertical or horizontal installations 1/2″ to 4″

Distributor Sealing Fitting Indonesia

Sealing Fitting Explosionproof &  Epoxy Sealing Compound Fllings to be used in hazardous area with the
following specifications:

  • Class I, Div. 1 & 2, Groups C, D

  • Seals vertical conduit risers into switchgear and motor control equipment and enclosures

  • Seals horizontal conduit runs at enclosures when used with TSC sealing compound

  • 1/2″ to 5″

Suplai Sealing Fitting Indonesia

EYS and EZS Series Explosionproof Conduit Sealing Fittings to be used in hazardous area with the
following specifications:

  • Class I, Div. 1 & 2, Groups A, B, C, D

  • Class II, Div. 1, Groups E, F, G

  • EYS for vertical only installations, or for both vertical or horizontal positions

  • EZS for installation at any angle

  • 1/2″ to 6″

jual sealing fitting

EYDX Explosionproof Conduit Sealing Fittings with Drain breather to be used in hazardous area with the
following specifications:

  • Class I, Div. 1 & 2, Groups B, C, D

  • Class II, Div. 1, Groups E, F, G

  • 40% wire fill capacity to allow uninterrupted runs in conduit system

  • Prevents accumulation of condensate above seal through continuous drainage

  • 1/2″ to 3″

       sealing fitting jakarta

EYD Explosionproof Sealing Fittings to be used in hazardous area with the following specifications:

  • Class I, Div. 1 & 2, Groups B, C, D

  • Class II, Div. 1, Groups E, F, G

  • Prevents accumulation of condensate above seal through continuous drainage

  • 1/2″ to 4″

jual sealing fitting

EYSA  Flameproof Conduit Sealing Fittings to be used in hazardous area with the following specifications:

  • For IEC electrical systems

  • Zone 1, 2, 21, 22

  • For vertical only installations, or for both vertical or horizontal positions

  • 20mm to 50mm

Jual  Sealing Fitting Crouse Hinds

EYSR Series Retrofit Sealing Fittings to be used in hazardous area with the
following specifications:

  • Class I, Div. 2 only, Groups C, D

  • Class II, Div. 2, Groups E, F, G

  • Replaces installed EYS or EYD sealing fitting without disassembly of conduit system

  • 3/4″ to 4″

Jual Sealing Fitting Explosion Proof Jakarta Exproof Indonesia

This seal fitting is an accessories for Installation
BAG Series Explosion-proof Seal Bushings
Catalogue number logic
Cable Glands and Bushings
Technical data
Explosion protection to
-CENELEC
-IEC
Can be used in
Zone 1 and Zone 2
Zone 21 and Zone 22
Ex d enclosure, copper-free aluminium, powder coated
external surface.
Widely used for isolating seal between pipes or pipes and
explosion-proof enclosures.Certifitace Atex Internasional / European ATEX Standart / American FM Standart
II 2 G Ex d IIC Gb
II 2 D Ex t IIIC Db IP66
DNV 12 ATEX_____; PCEC (China)
EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009
IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008
Copper-free aluminium; powder coated external surface.
Window grey (RAL 7040)
IP66

Explosion Proof Sealing Fitting Jakarta, Sealing Fitting Explosion Proof Jakarta, Sealing Fitting Explosion Proof G Type

Bag Series Explosion-Proof Seal Bushings
Catalogue Number Logic
Cable Glands And Bushings
Technical Data
Explosion Protection To
-Cenelec
-Iec
Can Be Used In
Zone 1 And Zone 2
Zone 21 And Zone 22
Ex D Enclosure, Copper-Free Aluminium, Powder Coated
External Surface.
Widely Used For Isolating Seal Between Pipes Or Pipes And
Explosion-Proof Enclosures.

Call Now